Non-Contact Compensating AC Voltage Stabilizer
Continuously monitoring the input voltage of the power grid line, the voltage detection unit converts any voltage changes into digital signals. These signals are then processed by the microcontroller, guided by preprogrammed instructions and predefined data. The intelligent control system then transmits commands to the optocoupler, activating the contactless and swift electronic switching circuit to precisely adapt the output voltage. This ensures that the output voltage remains within the acceptable error range, effectively maintaining automatic voltage stabilization.
- Input Frequency:50/60Hz
- Efficiency:≥98%
- Voltage Stabilizing Accuracy:±2%
- Response Speed:<10ms or <20ms
Description
Non-Contact Compensating AC Voltage Stabilizer / AC Static Automatic Voltage Regulator
Model: ZSBW (three phase), ZDBW (single phase)
A non-contact compensating AC voltage stabilizer is a type of voltage stabilizer that utilizes electronic switching technology to regulate output voltage without physically contacting the input voltage. It operates by continuously monitoring the input voltage and adjusting the switching of capacitors in the circuit to maintain the desired output voltage
Advantages
1. Extremely Fast Response and Stabilization Time
In contrast to traditional compensation AC voltage stabilizers, the WT-TBB reactive power compensation cabinet boasts exceptionally quick response and stabilization times. This remarkable responsiveness enables it to swiftly adapt to changes in input voltage, ensuring the stability of the output voltage. This rapid response is particularly crucial for applications that demand precise and uninterrupted voltage regulation.
2. Automated Bypass Switching in Response to Voltage Surges
The reactive power compensation cabinet is equipped with an intelligent control system that automatically switches to bypass mode when voltage surges occur. This fail-safe mechanism protects the device and the connected equipment from potential damage caused by excessive voltage transients. The seamless transition to bypass mode ensures uninterrupted power supply, maintaining system stability and preventing disruptions.
3. Extended Service Life and Minimal Maintenance
The reactive power compensation cabinet is designed for long-term operation with minimal maintenance requirements. Its robust construction and high-quality components contribute to its exceptional longevity. This translates into significant cost savings over the device’s lifetime, as it minimizes the need for frequent maintenance or replacements.
Specification
Non-contact Compensating AC Voltage stabilizer / Contactless Compensating AC Voltage Stabilizer
Technical data (three phase)
Input | Range | Three phase five wire 380V ± 15% (wider range can be customized) |
frequency | 50/60HZ | |
Transport Out | Rated voltage | Three phase 380V |
Voltage stabilizing accuracy | ±2% | |
response speed | <10ms | |
Additional voltage harmonic THD | No additional waveform distortion (static) | |
Efficiency | ≥98% | |
Three phase unbalance | Three phase voltage automatic balance | |
Delay output | Stabilize voltage before output (protect equipment from impact) | |
Protect | Overvoltage | When the output phase voltage exceeds 10%, it can be set to cut off the output or uninterrupted transferring to the bypass or no action, can be set |
Under voltage | When the output phase voltage is lower than 10%, it can be set to cut off the output or uninterrupted transferring to the bypass or no action, can be set | |
Lack of phase | automatic cut-off | |
Phase sequence error | Yes, digital phase detection technology is adopted, which is accurate and reliable, and can effectively avoid misoperation caused by harmonic interference | |
overload | Electronic detection, output can be cut off within 3 minutes of overload or uninterrupted transferred to the bypass, can be set | |
Over Current | Electronic detection and circuit breaker fulfill dual protection | |
short circuit | Electronic detection and circuit breaker fulfill dual protection | |
bypass | Uninterrupted automatic bypass | |
Display | Voltage | A、B、C、ΣABC three phases have true RMS touch screen display respectively |
electric current | A、B、C、ΣABC three phases have true RMS touch screen display respectively | |
working condition | Voltage stabilizing state/mains state | |
abnormal | Overvoltage, under voltage, overload, fuse failure, phase loss and phase dislocation | |
Operation mode | It has two working modes: voltage stabilization and mains power | |
Overload capacity | 1.2Times the rated current for 30 minutes | |
Interface | The intelligent man-machine interface operation panel is convenient for setting and querying various parameters |
Performance characteristics:
Fast response | 12Bit high-speed AD acquisition, 128 wave acquisition points per cycle, digital processing and operation by single chip microcomputer, and rapid compensation by electronic module |
Multiple adjustment modes can be set | Simultaneous regulation: when simultaneous regulation is set, AD simultaneously collects the true effective values of three-phase voltages a, B and C for average calculation, and gives instructions for compensation, which can effectively improve the imbalance of three-phase voltage |
Individual regulation: when individual regulation is set, the three-phase voltages are adjusted respectively to ensure that the three-phase voltages are within the accuracy range, especially suitable for single-phase load | |
Automatic judgment: microcomputer automatic analysis should carry out simultaneous or individual regulation. | |
Advanced measurement technology | 12Bit AD acquisition, digital filtering and true RMS calculation by single chip microcomputer |
Accurate control | Perfect cooperation between large-scale programmable logic device and single chip microcomputer |
Humanized Interface | Various indicators (output voltage, voltage stabilizing accuracy and protection function) can be set through the touch keys on the operation panel |
No distortion of output waveform | Contactless zero crossing switch switching, same frequency, phase locking and sine wave superposition compensation principle |
Resistance to harmonic interference | True RMS voltage detection |
Wide load range | Resistive, capacitive and inductive loads can be adapted |
Slow start and impact resistance | voltage stabilization first before output |
Full protection function | In case of overvoltage and Undervoltage, it can be protected within 1s or automatically switched to bypass without interruption, and has perfect phase loss, overload, short-circuit protection and sound alarm function after fault |
Voltage and current display | The true RMS values of voltage and current are displayed on the touchscreen |
Component brand:
Device name | Manufacturer | Device name | Manufacturer |
Thyristor | IR chip domestic packaging | air switch | Chint |
transformer | High quality silicon steel sheet is adopted | Control chip | ARM |
Non-contact Compensating AC Voltage stabilizer / Static Automatic Voltage Regulator
Technical data (Single phase):
Input | Range | Single phase 220V ± 15% (wider range can be customized) |
frequency | 50/60HZ | |
Transport Out | Rated voltage | Single phase 220V |
Voltage stabilizing accuracy | ±2% | |
response speed | <20ms | |
Additional voltage harmonic THD | No additional waveform distortion (static) | |
Efficiency | ≥98% | |
Delay output | Stabilize voltage before output (protect equipment from impact) | |
Protect | Over-voltage | When the output phase voltage exceeds 10%, it can be set to cut off the output or uninterruptedly transferring to the bypass or no action, can be set |
Under-voltage | When the output phase voltage is lower than 10%, it can be set to cut off the output or uninterruptedly transferring to the bypass or no action, can be set | |
Lack of phase | automatic cut-off | |
Phase sequence error | Yes, digital phase detection technology is adopted, which is accurate and reliable, and can effectively avoid misoperation caused by harmonic interference | |
overload | Electronic detection, output can be cut off within 3 minutes of overload or uninterruptedly transferred to the bypass, can be set | |
Overcurrent | Electronic detection and circuit breaker fulfill dual protection | |
short circuit | Electronic detection and circuit breaker fulfill dual protection | |
bypass | Uninterrupted automatic bypass | |
Display | Voltage | True RMS LCD display |
electric current | True RMS LCD display | |
working condition | Voltage stabilizing state/mains supply state | |
abnormal | Overvoltage, under voltage, overload, fuse failure, phase loss and phase dislocation | |
Operation mode | It has two working modes: voltage stabilization and mains power | |
Overload capacity | 1.2Times the rated current for 30 minutes | |
Interface | The intelligent man-machine interface operation panel is convenient for setting and querying various parameters |
Performance characteristics
Fast response | 12Bit high-speed AD acquisition, 128 wave acquisition points per cycle, digital processing and operation by single chip microcomputer, and rapid compensation by electronic module |
Advanced measurement technology | 12Bit AD acquisition, digital filtering and true RMS calculation by single chip microcomputer |
Accurate control | Perfect cooperation between large-scale programmable logic device and single chip microcomputer |
Humanized Interface | Various indicators (output voltage, voltage stabilizing accuracy and protection function) can be set through the touch keys on the operation panel |
No distortion of output waveform | Contactless zero crossing switch switching, same frequency, phase locking and sine wave superposition compensation principle |
Resistance to harmonic interference | True RMS voltage detection |
Wide load range | Resistive, capacitive and inductive loads can be adapted |
Slow start and impact resistance | It has the function of voltage stabilization before output |
Full protection function | In case of overvoltage and Undervoltage, it can be protected within 1s or automatically switched to bypass without interruption, and has perfect phase loss, overload, short-circuit protection and sound alarm function after fault |
Voltage and current display | True RMS LCD display of voltage and current respectively |
Component brand
Device name | manufacturer | Device name | manufacturer |
Thyristor | IR chip domestic packaging | air switch | chint |
transformer | High quality silicon steel sheet is adopted | Control chip | ARM |
Application Field
Applications of Non-Contact Compensating AC Voltage Stabilizer
- Distribution Systems:
By injecting capacitive reactive power into the system, it compensates for reactive power drawn by inductive loads, preventing voltage drops and ensuring a consistent supply of high-quality power to consumers.
- Industrial Facilities:
The WT-TBB reactive power compensation cabinet effectively manages these fluctuations, improving power factor and reducing energy consumption. This translates into significant cost savings for industrial operations.
- Data Centers:
The WT-TBB reactive power compensation cabinet ensures stable voltage levels and eliminates voltage fluctuations, preventing downtime and protecting sensitive equipment from potential damage.
- Renewable Energy Integration:
With the growing integration of renewable energy sources, such as wind and solar power, the WT-TBB reactive power compensation cabinet plays a vital role in grid stability and quality improvement.
- Microgrids and Smart Grids:
The WT-TBB reactive power compensation cabinet contributes to optimized power management and enhanced system stability in microgrids and smart grids. Controlling reactive power flow enables efficient power distribution and facilitates the integration of distributed energy resources.
Recommend
Now, let your business to a higher level, start professional consultation!
*We Will Reply To You Within 24 hours. Our working days are Mon.to Sat., 9:00 ~ 18:00.